Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (2024)

Digital timer relay or time delay relay, on-delay timer relay, has timing setting range of 0.01~9999 sec / 0.01~9999 min / 0.01~9999 hrs, easy to read with 4-digit dual time display. High quality and accuracy digital timer relay / countdown timer is widely applied in the industrial automation field with power supply 24V DC or 85-265V AC.

Specification

ModelATO-TH100
Mode of OperationOn delay timer relay
Supply Voltage (Optional)85V-265V ACor 24V DC
Output Mode (Optional)Mode 1: External connecting reset, one group pause delay output
Mode 2: One group instantaneous and one group delay output
Mode 3: One group suspension delay output
Mode 4: Two groups sync delay output
Time Setting Range0.01~9999 second/minute/hour
Display Mode4-digit display
Contact Capacity220VAC/3A 28VDC/5A (Resistive Load)
Power Comsuption≤2W
Mounting TypePanel Mount
DimensionsExternal (W*H*D)48*48*73mm
Cut-Out (W*H)45*45mm
Accessary (Optional)8-pin Mounting Socket
Weight1kg
Operating Temperature-10 ~ 50℃
Humidity≤85% no caustic or magnetic interference

Dimensions (Unit: mm)

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (1)

Connection Diagram & Output Operation Mode

Mode 1: External connecting reset, one group pause delay output

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (2)

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (3)

Mode 2: One group instantaneous and one group time delay output Mode 3: One group suspension delay output

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (4) Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (5)Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (6)

Mode 4: Two group sync time delay output

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (7)Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (8)

Details

Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (9)

Tips: How to select a timer relay?

The selection of timer relay mainly focuses on delay mode and parameter. The following aspects should be considered when selecting a time delay relay.

1. Selection of delay mode
There are two types of timer relays, power-on delay or power-off delay, which should be selected according to the requirements of the control circuit. The reset time after the action should be longer than the inherent action time, so as to avoid misoperation or even no delay, which is especially important in the case of repeated delay circuits and frequent operations.

2. Timer relay type selection
For occasions with low requirements for delay time accuracy, generally use electromagnetic or air damping time delay relays with lower prices; otherwise, for high requirements on time delay accuracy, electronic time relays can be used.

3. Coil voltage selection
Select the voltage of the relay's attraction coil including 12VDC / 24VDC / 110VAC / 220VAC, etc., according to the voltage of the control circuit.

4. Selection of power parameter changes
Air damping or electric time relays are better than transistors for occasions with large power supply voltage fluctuations, and electric time relays are not suitable for occasions with large power frequency fluctuations, and air damping timer relay is not suitable for large temperature changes.

See the video below for the use of ATO digital timer relay.

ATO-TH300 Digital Timer Relay User Manual.pdf

Existing reviews of Digital Timer Relay, 8 Pin, 24V DC/110-240V AC

Multi-voltage compatible

The impressive digital timing relay not only supports 24V DC, but also adapts to a wide voltage range of 110-240V AC. This flexibility makes it easy to cope in a variety of industrial and domestic scenarios, making it a capable assistant in the field of electrical control.

From:Mrthos | Date: 23/11/2023

Was this review helpful? Yes No (0/0)

Smaller than i expected

The timer relay looked great, but smaller package than the illustration looked like.

From:Leo | Date: 24/10/2023

Was this review helpful? Yes No (0/0)

Nice digital timer relay

It has been five months since I bought this digital timer relay.There is no problem using this relay in hot weather. It's light and easy for me to carry.

From:Gammon | Date: 08/11/2022

Was this review helpful? Yes No (0/0)

Very effective and durable digital timer relay

I work in automation and need a digital timer relay. This is also the first time I buy a relay in ATO. This one is definitely the best one I have used and reliable most importantly.

From:Shaun | Date: 21/10/2022

Was this review helpful? Yes No (0/0)

Timer relay with full functionality

This timer relay is simple and can be connected to a simple loop timer function. Cheap price. It is very easy to connect and program.

From:Ignacio | Date: 29/04/2022

Was this review helpful? Yes No (0/0)

For my project setup...

For my project setup, I want to activate one actuator, then the next actuator activates a specific amount of time later. Do you know of a way to hook up my system like this?

From:Christopher | Date: 12/10/2020

Was this review helpful? Yes No (0/0)

ATO Responded

Yes, you can just use our digital timer relay to realize your setup.

Timer relay with normally closed contacts

For timer relay of model: ATO-TIMER-TH100, I need on normally closed contacts then open when timer goes to zero . Can it fulfill that?

From:Steve | Date: 03/08/2020

Was this review helpful? Yes No (0/0)

ATO Responded

Yes, this time relay has this function >>>> On normally closed contacts then open when timer goes to zero.
And If you need a group of normally closed contacts, you can choose mode 2 option, but if you need 2 groups of normally closed contacts, you can choose mode 4.

Timer relay operation

Can your timer display count down and time delay under operation?

From:Paul | Date: 06/04/2020

Was this review helpful? Yes No (0/0)

ATO Responded

Yes, our timer can display delay time and also can display the count down time during the operation, and also you can set how long the output remains after the delay time reaches!

Which model of timer relay should we choose?

Hello, which model of timer relay should we choose for a greenhouse? We live in Europe (220V) and we would like to switch on a humidifier (220V) every 5 Minutes for one minute and a fan in a similar cycle.

From:Stephen | Date: 31/10/2019

Was this review helpful? Yes No (0/0)

ATO Responded

Hello, my dear friend. The model ATO-TIMER-TH100 timer relay is suitable for your required function, as you can set both delay time (SV) and an output delay time (T).

Load more reviews...

Write your review for Digital Timer Relay, 8 Pin, 24V DC/110-240V AC

  • Only registered users can write reviews

  • Bad
  • Excellent
Digital Timer Relay, 8 Pin, 24V DC/110-240V AC (2024)
Top Articles
Latest Posts
Article information

Author: Catherine Tremblay

Last Updated:

Views: 6498

Rating: 4.7 / 5 (47 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Catherine Tremblay

Birthday: 1999-09-23

Address: Suite 461 73643 Sherril Loaf, Dickinsonland, AZ 47941-2379

Phone: +2678139151039

Job: International Administration Supervisor

Hobby: Dowsing, Snowboarding, Rowing, Beekeeping, Calligraphy, Shooting, Air sports

Introduction: My name is Catherine Tremblay, I am a precious, perfect, tasty, enthusiastic, inexpensive, vast, kind person who loves writing and wants to share my knowledge and understanding with you.